Follow us :

W- 304 Hooked end Steel Fiber

W- 304 Hooked end Steel Fiber
W- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel Fiber
group name
Reinforcement Refractory Steel fiber
Min Order
100 kilogram
brand name
HARVEST Refractory Manufacturer
model
W-304/30/.40HE
Nearest port for product export
Dalian port, Xingang port, Bayuquan port, Yingkou port
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW
Acceptable payment methods
T/T, L/C, D/P D/A
update time
Thu, 26 Dec 2024 15:13:18 GMT

Paramtents

  • Length 30mm

  • Equivalent Diameter 0.4mm

  • Shape Hooked ends

  • Cross-sectional area shape Round

  • Tensile strength 1400Mpa min

  • Aspect ratio 75

Packging & Delivery

  • Min Order100 kilogram

Briefing

hot sale W- 304 Hooked end Steel Fiber

Detailed

Harvest’s “W-series” Steel Fibre Product Data Sheet

 

W-304/30/.40HE

 

  

Harvest’s “W-series” fibres are cold drawn wire fibres for refractories materials for the high temperature processing industries (Metallurgy, petrochemical, cement, glass, power station and other furnaces).

 

 

Chemical Analysis (%):

 

Alloy No.

Cr

Ni

C≤

Si≤

Mn≤

P≤

S≤

304

24-26.00

19-22.00

0.08

1.5

2.0

0.045

0.030

 

*Other materials :430/304/330/316…& low carbon steel  can be manufactured specifically to suit customer’s requirements.

 

  

Service Temperature:

 

Melting Point

Recommended Maximum Service Temperature

304

1380-1455℃

Cyclic Heating

1000℃

Continuous Service

850℃

 

 

Dimensions: 

  • Lengths are 6/10/15/25/30/50/60mm. Other lengths can be manufactured specifically to suit customer’s requirements.

  • Equivalent diameter 0.2/0.4/0.5/0.6/0.75/1.0mm. Other diameters can be manufactured specifically to suit customer’s requirements.

 

Packing: 

  • Fibres are packed in 1/5/10/20kg cartons then put on pallets. Other packaging can be supplied if requested.

Using method and using quantity: 

  • Usually use 0.2-2% ( volume ) of steel fiber in refractories or concrete materials, mixed evenly to maximize the use effect of steel fiber into full play. Mix method :1. Wet mix; 2. Dry mix.
  • In order to prevent  explosions & radiation for concrete buildings , it is recommended to use steel fibres number 40-60% (volume).

Health & Safety:

  • USING STEEL FIBRES UNDER NORMAL CONDITIONS DOES NOT PRESENT AN INHALATION, INGESTION OR CONTACT HEALTH HAZARD.

  • BECAUSE OF THEIR PHYSICAL NATURE, WE RECOMMEND THAT OPERATIVES HANDLING THE FIBRES SHOULD ALWAYS WEAR GLOVES.

  • TO AVOID DETERIORATION OF PACKING, THE FIBRES SHOULD BE STORED IN A DRY ENVIRONMENT.

TO AVOID DETERIORATION OF PACKING, THE FIBRES SHOULD BE STORED IN A DRY ENVIRONMENT.

.jpg

.jpg

.jpg

235095-1301150P34930_.jpg